skip to main content
Show Results with:

Re-evaluation assessment of a large volume sampling (LVS) system for the determination of petroleum hydrocarbons and their stable carbon isotopes in deep-sea watersElectronic supplementary information (ESI) available. See DOI: 10.1039/c9ay00983c

Tolosa, Imma et al.

Analytical methods. Volume 11:Issue 31 (2019); pp 3943-3957 -- RSC Publishing

Online access

  • Title:
    Re-evaluation assessment of a large volume sampling (LVS) system for the determination of petroleum hydrocarbons and their stable carbon isotopes in deep-sea watersElectronic supplementary information (ESI) available. See DOI: 10.1039/c9ay00983c
  • Author: Tolosa, Imma;
    Guitart, Carlos;
    Mesa-Albernas, Marianela;
    Funkey, Carolina;
    Cassi, Roberto
  • Found In: Analytical methods. Volume 11:Issue 31 (2019); pp 3943-3957
  • Journal Title: Analytical methods
  • Subjects: Analytical biochemistry--Periodicals; Chemical laboratories--Standards--Periodicals; Chemistry, Analytic--Periodicals; Dewey: 543.1905
  • Rights: Licensed
  • Publication Details: RSC Publishing
  • Abstract:

    We have revisited the large volume sampling (LVS) technique and its analytical methodologies to develop and validate (step by step) a home-made solid-phase extraction (SPE) system (Amberlite® XAD-2 resin-based) connected to a particle collectorin situpump (McLane WTS-LV04) for high sample pre-concentration and determination of chemical contaminants (e.g.aliphatic and aromatic petroleum hydrocarbons) and their 13 C/ 12 C isotope ratio. The SPE laboratory extraction/elution procedure was newly adapted from the Bligh and Dyer method to facilitate the removal of the residual water derived from the sampling. The comprehensive sampling and analytical method was validated in the framework of a "top-down" single-laboratory approach using coastal seawater samples. In the dissolved phase of seawater, full quantitative validation was achieved for semi-volatile polycyclic aromatic hydrocarbons (PAHs; from naphthalene to methylpyrene) by gas chromatography mass spectrometry (GC-MS). The LVS approach was also validated for performing compound-specific stable 13 C/ 12 C ratio measurements by gas chromatography (combustion) isotope ratio mass spectrometry (GC-C-IRMS). Overall, both the long field sampling and analytical operational times, as well as the blank levels and interference from resins might restrict this LVS technique as a routine procedure for monitoring contaminants in seawater, but for research and non-routine measurements it will still be the state of the art to investigate and trace unknown chemical contaminants in deep sea marine environments.


  • Identifier: System Number: ETOCvdc_100086328032.0x000001; Journal ISSN: 1759-9660; 10.1039/c9ay00983c
  • Publication Date: 2019
  • Physical Description: Electronic
  • Shelfmark(s): 0897.103700
  • UIN: ETOCvdc_100086328032.0x000001

Searching Remote Databases, Please Wait